Jkzr-1 cone penetration tester
Number of views:587
QR code:

Add time:2021-10-31
Brief description:
1. Asphalt: The sample is placed in a constant temperature bath at 25 ℃± 0.1 ℃, and a standard needle with a load of 100 grams ± 0.05 grams is vertically moved without obvious friction. The depth of penetration into the asphalt sample within 5 seconds is called the asphalt penetration degree to identify the viscosity of the asphalt. The greater the penetration of asphalt, the lower the viscosity of asphalt, and the softer the asphalt.
2. Lubricating grease: The depth at which the sample is placed in a constant temperature bath at 25 ℃± 0.1 ℃ and a standard cone with a load of 150 grams moves vertically without obvious friction and sinks into the lubricating grease or petroleum grease within 5 seconds is called the cone penetration degree of lubricating grease or petroleum grease, which is used to identify the softness and hardness of the lubricating grease or petroleum grease. In addition to the two main uses mentioned above, this instrument can also be used for the inspection of solid particles, powders, colloids, frozen bodies and other materials, as well as food raw materials such as cheese, sugar gum, butter, malt extract, cream, fermented bodies, etc. It can be widely used in the food industry, transportation and highway engineering, and other industrial sectors.
Main technical indicators
1. Measurement range: (0-600) needle penetration;
2. Needle insertion time control device: can select 5 seconds, 8 seconds, 10 seconds, 12 seconds, 30 seconds, and 60 seconds respectively, with a time error of less than ± 0.1 seconds;
3. Resolution: 0.01mm;
4. Needle insertion accuracy: ± 1 needle insertion degree;
5. Heater power: 200W;
6. Temperature control accuracy: 25 ℃± 0.1 ℃ (note: the ambient temperature should not exceed 20 ℃);
7. Temperature control method: high-precision digital temperature controller;
8. Thermostatic bath: for hard glass tanks;
9. Stirring: Magnetic stirring beads automatically stir;
10. Standard needle: configured according to different standard requirements
11. Sample dish: configured according to different standard requirements
12. Weights: configured according to different standard requirements
13. Temperature gauge: configured according to different standard requirements 15. Standard cone: 102.5g ± 0.05g
14. Lifting bracket: dual lifting and adjusting mechanism for coarse and fine adjustment, facilitating the alignment of the needle tip with the sample plane;
15. Working power supply: AC (220 ± 10%) V, 50Hz, power consumption not exceeding 300W;
16. Dimensions: 280mm x 350mm x 700mm (length x width x height);
17. Other: Equipped with a cold light source and magnifying glass for easy use and operation.


SERVICE HOTLINE 

Home
Phone
Product